ElectrIQ AIRCUBE Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Split-System-Klimaanlagen ElectrIQ AIRCUBE herunter. The Multivariable Air Flow Meter AIRcube Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Specifications are subject to change without notice. - 1 - First issue: Oct. 2004 Rev.1: Oct. 2004
No. SS2-MVC200-0100 (Rev.1)
OVERVIEW
The Multivariable Mass Flow Meter AIRcube, a
compact flow meter has all function necessary to
measure nitrogen (N
2
) gas and air. The model
MVC10A/MVC10F can accurately measure
differential pressure, static pressure, and process
temperature to dynamically calculate fully
compensated mass flow of factory compressed
air, and N
2
gas in food and beverage for anti-
oxidation.
The model MVC10A/MVC10F is very useful to
save energy with indicating cost of air and N
2
and leak-check function.
FEATURES
High accuracy
A state-of-the-art Dual Sensor realizes accurate
measurement of mass flow rate by measuring Differential
Pressure (DP), Gauge Pressure (GP), and Temperature (T)
for the density compensation.
Full display function
Model MVC10A/MVC10F can display volume flow and
mass flow, and velocity or pressure.
Stable measurement
The streamline shaped flow tube (etube) can minimize
the scaling and the clogging.
Output is with excellent reproducibility due to smooth
and stable streamline by elliptic tube. The rangeability
of flow rate is as wide as 1 to 30, so measurement is
possible down to almost zero flow rate.
Even with a short upstream length, it provides high
accuracy.
Unique functions
Cost indication
To save energy management, it has cost indication.
Auto ranging function
The measuring range can automatically set with
memorizing maximum flow even if the actual flow rate
is unknown.
Leak check function
Measuring pressure in pipe with built-in pressure sensor,
indicate leak rate necessary to economize energy.
APPLICATIONS
Measuring air flow each manufacturing process
Promoting economized energy to grasp actual
consumption of air each factory and shop
Observing capacity of equipment
Measuring flow of N
2
gas
PRINCIPLE
The AIRcube is a differential pressure flow meter based
on the Bernoulli theorem.
Flow (Q) is calculated by the following equation.
ρ
: Actual differential pressure
P : Density of air
P1 : Primary pressure
T1 : Temperature
A : Flow coefficient
QAP()
ρ
=
ρ
P1 101.325+()
101.325
-------------------------------------
273.15
273.15 T1+()
----------------------------------
×=
The Multivariable Air Flow Meter AIRcube
Model MVC10A / MVC10F
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - Model MVC10A / MVC10F

Specifications are subject to change without notice. - 1 - First issue: Oct. 2004 Rev.1: Oct. 2004No. SS2-MVC200-0100 (Rev.1)OVERVIEWThe Multivariable

Seite 2 - Converter specifications

No. SS2-MVC200-0100 (Rev.1) Yamatake Corporation- 2 -Detector specificationsSize: 50, 65, 80, 100, 150 mmWetted material: SCS13Measuring fluid: Compre

Seite 3 - Installation specifications

Yamatake Corporation No. SS2-MVC200-0100 (Rev.1)- 3 -Installation specificationsPressure limits: 0.05 to 0.98 MPaG (remote type: 0.05 to 0.9 MPaG)Ambi

Seite 4 - Electrical wiring

No. SS2-MVC200-0100 (Rev.1) Yamatake Corporation- 4 -MODEL SELECTIONSThe Multivariable Air Flow Meter AIRcubeBasic model no. Selections OptionsElectri

Seite 5 - DIMENSIONS

Yamatake Corporation No. SS2-MVC200-0100 (Rev.1)- 5 -DIMENSIONSModel MVC10A horizontal installation [Unit: mm]Model MVC10A vertical installationDimens

Seite 6 - Model MVC10F [Unit: mm]

No. SS2-MVC200-0100 (Rev.1) Yamatake Corporation- 6 -Model MVC10F [Unit: mm]MaterialsKey no. Part name Material1Case ADC 122 Case lid Polycarbonate3 C

Seite 7 -  CAUTION

Yamatake Corporation No. SS2-MVC200-0100 (Rev.1)- 7 -Installation PrecautionsObey following precautions to prevent accidents, and for product to funct

Seite 8 - Advanced Automation Compan

This has been printed on recycled paper.Advanced Automation Company1-12-2 Kawana, FujisawaKanagawa 251-8522 JapanURL:http://www.azbil.com